  1 0 1 p ort ol a a ven u e , l i ve r mo re , ca 9 45 51 ? te l: (9 25 ) 58 3 - 840 0 ? fa x: ( 92 5) 5 83 - 84 0 1 ? www. b r id ge lu x.c om b ridgelux rs array series product data sheet ds25 bxra - xxx - 3500 - f, bxr a - xxx 4 000 - h , bxra - xxx 7000 - j , bxra - 40e 4000 - f, bxra - 40e 4500 - h , bxra - 40e 7500 - j , bxra - xxc4500 - f, bxra - x x c5300 - h, bx ra - x x c9000 - j i ntroduction the bridgelux family of led array products delivers high performance, compact and cost - effective solid - state lighting solutions to serve the general lighting market. these products combine the higher efficacy, lifetime, and reliability benefits of leds with the light output levels of many conventional lighting sources. the bridgelux rs array series has been specified to enable la mp and luminaire designs with comparable performance to existing high wattage cfl and hid conventional light sources for retail, commercial, industrial and outdoor/street li ghting applications. bridgelux arrays are ideal for all types of light - on - demand a pplications, where they can be instantaneously and smoothly dimmed up or down without any effect on lifetime , unlike traditional cfl and hid light sources . bridgelux rs array series are a high performance alternative to conventional solid state solutions, delivering between 3,000 and 10, 0 00 lumens under application conditions in warm, neutral and cool white color temperatures. these compact high flux density light sources deliver uniform high quality illumination without pixilation or the multiple shadow e ffect caused by led component based solutions, enabling excellent beam control for precision lighting . led array solutions reduce system complexity and enable miniaturized cost - effective designs. luminaire designs incorporating these led arrays deliver system level p erformance comparable to 42 - 55 watt cfl, 35 - 90 watt low pressure sodium, 70 - 150 watt high pressure sodium or 70 - 200 watt metal halide based luminaires and feature increased system level and service life. typical applications include retail l ighting, commercial down lights, high bay, outdoor and street lights, and entertainment lighting. features ? compact high flux density light source ? uniform high quality illumination ? minimum 70, 80 and 90 cri options ? streamlined thermal path ? energy star / ansi compliant color binning structure with 3sdcm options ? more energy efficient than incandescent, halogen and fluorescent lamps ? low voltage dc operation ? instant light with unlimited dimming ? 5 - y ear warranty ? rohs compliant and pb free benefits ? enhanced optical control ? clean white light without pixilation ? high quality true color reproduction ? significantly reduced thermal resistance and increased operating temperatures ? uniform consistent white light ? lower operating costs ? ul recognized ? easy to use with daylight and motion detectors to enable increased energy savings ? reduced maintenance costs ? environmenta lly friendly, no disposal issue
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 2 of 28 table of contents page typical product features 3 product nomenclature 3 ce recognition 4 selection guid e 6 typical performance at alternative drive currents 7 flux characteristics 10 electrical characteristics 11 absolute maximum ratings 12 forward current versus voltage characteristics 14 figure 2: typical current vs. voltage 14 typical relative luminous flux vs. current 16 typical chromaticity characteristics vs. temperature 18 typical radiation pattern 20 typical spectral characteristics 21 mechanical dimensions 22 color binning information 23 co lor control options 26 design resources 27 about bridgelux 28
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 3 of 28 typical product features b ridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. the rs array is the largest chip - on - board device in the bxra led array product series. the arrays incorporate severa l features to simplify design integration and assembly. figure 1: array features product nomenclature the part number designation for bridgelux led a rray s is explained as follows: bxra C ab c defg C h C ij where: b x r a C designates product family a b C designates the nominal ansi color temperature; 27 = 2700k; 30 = 3000k, etc. c - designates minimum cri; c = 70, e = 80, g = 90 d e f g - designates nominal flux; 4000 = 4000 lm, 7000 = 7 000lm, etc. h C designates configuration i j C designates cct color binning 03 = 3sdcm or 3 - step 04 = 4sdcm or 4 - step 00 = 7sdcm or 7 - step solder pad mounting holes case temperature (tc) measurement point yellow phosphor light emitting surface (les) polarity indication simplifies assembly instructions fully engineered substrate for consistent thermal, mechanical and optical properties manufacturer identification: genuine bridgelux index features assist accurate orientation during assembly solder pad white ring around les note: part number and lot codes are scribed on back of array
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 4 of 28 lumen maintenance characteristics bridgelux projects that its family of led array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. this performance assumes constant current operation at the nominal drive current with case temperature maintained at or below 85c. for use beyond these typical operating conditions pleas e consult your bridgelux sales representative for further assistance. these projections are based on a combination of package test data, semiconductor chip reliability data, a fundamental understanding of package related degradation mechanisms, and perfor mance observed from products installed in the field using bridgelux die technology. bridgelux conducts lumen maintenance tests per lm80. observation of design limits is required in order to achieve this projected lumen maintenance. environmental complian ce bridgelux is committed to providing environmentally friendly products to the solid state lighting market. bridgelux led arrays comply with the european union directives on the restriction of hazardous substances in electronic equipment, namely the roh s directive. bridgelux does not intentionally add the following restricted materials to led array products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (pbb) or polybrominated diphenyl ethers (pbde). ul recognition bridgelux secu res ul recognition for all the led array products. please refer to the ul file e350613 for the latest list of ul recognized arrays. bridgelux uses ul recognized materials with suitable flammability ratings in the led array to streamline the process for c ustomers to secure ul listing of the final luminaire product. ce recognition in accordance with the relevant european union directives, the family of led array products conform to the applicable requirements of the iec/en 62031:2008 (led modules for general lighting safety specifications) and iec 62471:2006 (photobiological safety of lamps and lamp systems). bridgelux maintains a ce declaration of conformity statement on its website and displays the ce mark on product packing labels. minor product ch ange policy the rigorous qualification testing on products offered by bridgelux provides performance assurance. slight cosmetic changes that do not affect form, fit, or function may occur as bridgelux continues product optimization. ca se temperature measur ement point a case temperature (t c ) measurement point location is included on the top surface of the bridgelux led arrays. the location of this measurement point is indicated in the mechanical dimensions section of this data sheet. the purpose of this mea surement point is to allow the user access to a measurement point closely linked to the true case temperature on the back surface of the led array. once the led array is installed, it is challenging to measure the back surface of the array, or true case t emperature. bridgelux has provided the case temperature measurement location in a manner which closely ties it to the true case temperature of the led array under steady state operation. deviations between thermal measurements taken at the point indicat ed and the back of the led array differ by less than 1c, providing a robust method to testing thermal operation once the product is installed.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 5 of 28 cautionary statements caution: contact with optical area avoid any contact with the optical area. do not to uch the optical area of the led array or apply mechanical stress to the yellow phosphor resin area C it could damage the led array. optics and reflectors must not be mounted in contact with the yellow phosphor resin area (les) or the white ring that surro unds the yellow phosphor area. using the white ring to secure optics can result in damage to the led array as the ring is not designed to act as a mechanical locating feature. optical devices may be mounted on the top surface of the led array substrate o utside of the white ring maximum od as specified in the product data sheet. use the mechanical features of the led array substrate edges and/or mounting holes to locate and secure the optical device as needed. caution: eye safety eye safety classificati on for the use of bridgelux led arrays is in accordance with iec specification en62471; photobiological safety of lamps and lamp systems. bridgelux led arrays are classified as risk group 1 (low risk) when operated at or below their rated test current. p lease use appropriate precautions. it is important that employees working with leds are trained to use them safely. caution: risk of burn do not touch the led array or resin area during operation. allow the led array to cool for a sufficient period of time before handling. the led array may reach elevated temperatures such that it can burn skin when touched. caution: chemical exposure ha zard exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the led array. please consult application note an11 for additional information.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 6 of 28 selection guide the following configurations are available : table 1: selection guide for rs arrays part number [1] cct [2] (kelvin) cri [3 ,4 ] test current [5] (ma) typical voltage (v) typical flux [6] (lm) typical power [6 ] (w) typical efficacy [6 ] (lm/w) t j = 25oc t case = 85oc bxra - 27e3500 - f - 03 2700k 80 1750 17.9 2900 2520 31.3 93 bxra - 27e4000 - h - 03 2700k 80 2100 23.5 4640 4040 49.4 94 bxra - 27e7000 - j - 03 2700k 80 2800 29.4 7320 6370 82.3 89 bxra - 27g3500 - f - 03 2700k 90 1750 17.9 2520 2190 31.3 80 bxra - 27g4000 - h - 03 2700k 90 2100 23.5 3960 3440 49.4 80 bxra - 27g7000 - j - 03 2700k 90 2800 29.4 6280 5460 82.3 76 bxra - 30e3500 - f - 03 3000k 80 1750 17.9 3150 2740 31.3 101 bxra - 30e4000 - h - 03 3000k 80 2100 23.5 5040 4380 49.4 102 bxra - 30e7000 - j - 03 3000k 80 2800 29.4 8050 7000 82.3 98 bxra - 30g3500 - f - 03 3000k 90 1750 17.9 2790 2430 31.3 89 bxra - 30g4000 - h - 03 3000k 90 2100 23.5 4260 3700 49.4 86 bxra - 30g7000 - j - 03 3000k 90 2800 29.4 6800 5910 82.3 83 bxra - 35e3500 - f - 03 3500k 80 1750 17.9 3280 2850 31.3 105 bxra - 35e4000 - h - 03 3500k 80 2100 23.5 5340 4640 49.4 108 bxra - 35e7000 - j - 03 3500k 80 2800 29.4 8530 7420 82.3 104 bxra - 40e4000 - f - 03 4000k 80 1750 17.9 3530 3070 31.3 113 bxra - 40e4500 - h - 03 4000k 80 2100 23.5 5700 4960 49.4 116 bxra - 40e7500 - j - 03 4000k 80 2800 29.4 9010 7840 82.3 109 bxra - 50c4500 - f - xx 5000k 70 1750 17.9 3940 3430 31.3 126 bxra - 50c5300 - h - xx 5000k 70 2100 23.5 6300 5480 49.4 128 bxra - 50c9000 - j - xx 5000k 70 2800 29.4 10060 8750 82.3 122 bxra - 56c4500 - f - xx 5600k 70 1750 17.9 3840 3340 31.3 123 bxra - 56c5300 - h - xx 5600k 70 2100 23.5 6300 5480 49.4 128 bxra - 56c9000 - j - xx 5600k 70 2800 29.4 10060 8750 82.3 122 note for table 1 through 5 (additional specific notes following table 2 through 5): 1. part numbers with - xx suffix are available with multiple color control options ( 4 sdcm or 7 sdcm for example). 2. nominal cct as defined by ansi c78.377 - 2011. 3. values are minimum . 4. minimum r9 value for 90 cri products is 50. 5. products tested under pulsed condition (10ms pulse width) at rated test current where t junction = t case = 25c. 6. typical performance values are provided as a reference only and are not a guarantee of performance. 7. bridgelux maintains a 7% tolerance on flux measurements. 8. operating these led arrays at or below the drive currents listed in table 2 and 5, with a case temperature maintained at or below 85c, will enable the average lumen maintenance projection outlined earlier in this product data sheet.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 7 of 28 typical performance at alternative drive currents customers may drive the led arrays at alternative drive currents dependent on the specific application. the typical performance at any drive current can be derived from the current vs. voltage characteristics shown in figures 2 and 3 and from the flux versus current characteristics shown in figure 8 and 9. the typical performance at common drive currents is summarized in table 2. table 2: typical product performance at alternative drive currents part number [1] cct & cri current [9] (ma) typical voltage [6] (v) typical power [6] (w) typical flux [6] (lm) typical efficacy [6] (lm/w) t j = 25oc t j = 25oc t j = 25oc t case = 85oc t j = 25oc bxra - 27e3500 - f - 03 2700k and 80 cri 1050 17.2 18.0 1820 1580 101 1400 17.5 24.5 2370 2060 97 1750 17.9 31.3 2900 2520 93 2100 18.3 38.3 3410 2970 89 bxra - 27e4000 - h - 03 2700k and 80 cri 1400 22.7 31.7 3170 2760 100 1750 23.1 40.4 3920 3410 97 2100 23.5 49.4 4640 4040 94 2450 23.8 58.4 5230 4550 90 bxra - 27e7000 - j - 03 2700k and 80 cri 1400 27.8 38.9 3770 3280 97 2100 28.6 60.1 5590 4870 93 2800 29.4 82.3 7320 6370 89 3150 29.7 93.7 8060 7020 86 bxra - 27g3500 - f - 03 2700k and 90 cri 1050 17.2 18.0 1580 1370 88 1400 17.5 24.5 2060 1790 84 1750 17.9 31.3 2520 2190 80 2100 18.3 38.3 2970 2580 77 bxra - 27g4000 - h - 03 2700k and 90 cri 1400 22.7 31.7 2700 2350 85 1750 23.1 40.4 3340 2900 83 2100 23.5 49.4 3960 3440 80 2450 23.8 58.4 4460 3880 76 bxra - 27g 7000 - j - 03 2700k and 90 cri 1400 27.8 38.9 3240 2820 83 2100 28.6 60.1 4800 4170 80 2800 29.4 82.3 6280 5460 76 3150 29.7 93.7 6920 6010 74 bxra - 30e3500 - f - 03 3000k and 80 cri 1050 17.2 18.0 1980 1720 110 1400 17.5 24.5 2570 2240 105 1750 17.9 31.3 3150 2740 101 2100 18.3 38.3 3710 3220 97 bxra - 30e4000 - h - 03 3000k and 80 cri 1400 22.7 31.7 3440 2990 108 1750 23.1 40.4 4250 3700 105 2100 23.5 49.4 5040 4380 102 2450 23.8 58.4 5680 4930 97
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 8 of 28 table 2 continued part number [1] cct & cri current [9] (ma) typical voltage [6] (v) typical power [6] (w) typical flux [6] (lm) typical efficacy [6] (lm/w) t j = 25oc t j = 25oc t j = 25oc t case = 85oc t j = 25oc bxra - 30 e 7000 - j - 03 3000k and 80 cri 1400 27.8 38.9 4150 3610 107 2100 28.6 60.1 6150 5350 102 2800 29.4 82.3 8050 7000 98 3150 29.7 93.7 8870 7710 95 bxra - 30g3500 - f - 03 3000k and 90 cri 1050 17.2 18.0 1750 1530 97 1400 17.5 24.5 2280 1990 93 1750 17.9 31.3 2790 2430 89 2100 18.3 38.3 3280 2860 86 bxra - 30g4000 - h - 03 3000k and 90 cri 1400 22.7 31.7 2910 2530 92 1750 23.1 40.4 3600 3120 89 2100 23.5 49.4 4260 3700 86 2450 23.8 58.4 4800 4170 82 bxra - 30g7000 - j - 03 3000k and 90 cri 1400 27.8 38.9 3510 3050 90 2100 28.6 60.1 5200 4520 87 2800 29.4 82.3 6800 5910 83 3150 29.7 93.7 7490 6510 80 bxra - 35e3500 - f - 03 3500k and 80 cri 1050 17.2 18.0 2060 1790 114 1400 17.5 24.5 2680 2330 109 1750 17.9 31.3 3280 2850 105 2100 18.3 38.3 3860 3350 101 bxra - 35e4000 - h - 03 3500k and 80 cri 1400 22.7 31.7 3650 3170 115 1750 23.1 40.4 4510 3920 112 2100 23.5 49.4 5340 4640 108 2450 23.8 58.4 6020 5230 103 bxra - 35e7000 - j - 03 3500k and 80 cri 1400 27.8 38.9 4400 3830 113 2100 28.6 60.1 6520 5670 108 2800 29.4 82.3 8530 7420 104 3150 29.7 93.7 9400 8170 100 bxra - 40e4000 - f - 03 4000k and 80 cri 1050 17.2 18.0 2220 1930 123 1400 17.5 24.5 2890 2510 118 1750 17.9 31.3 3530 3070 113 2100 18.3 38.3 4150 3610 108 bxra - 40e4500 - h - 03 4000k and 80 cri 1400 22.7 31.7 3890 3390 123 1750 23.1 40.4 4810 4190 119 2100 23.5 49.4 5700 4960 116 2450 23.8 58.4 6420 5590 110
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 9 of 28 table 2 continued part number [1] cct & cri current [9] (ma) typical voltage [6] (v) typical power [6] (w) typical flux [6] (lm) typical efficacy [6] (lm/w) t j = 25oc t j = 25oc t j = 25oc t case = 85oc t j = 25oc bxra - 40e7500 - j - 03 4000k and 80 cri 1400 27.8 38.9 4650 4040 119 2100 28.6 60.1 6880 5990 114 2800 29.4 82.3 9010 7840 109 3150 29.7 93.7 9920 8640 106 bxra - 50c4500 - f - xx 5000k and 70 cri 1050 17.2 18.0 2470 2150 137 1400 17.5 24.5 3220 2800 131 1750 17.9 31.3 3940 3430 126 2100 18.3 38.3 4640 4040 121 bxra - 50c5300 - h - xx 5000k and 70 cri 1400 22.7 31.7 4300 3740 136 1750 23.1 40.4 5320 4620 132 2100 23.5 49.4 6300 5480 128 2450 23.8 58.4 7100 6170 122 bxra - 50c9000 - j - xx 5000k and 70 cri 1400 27.8 38.9 5190 4510 133 2100 28.6 60.1 7690 6690 128 2800 29.4 82.3 10060 8750 122 3150 29.7 93.7 11080 9640 118 bxra - 56 c4500 - f - xx 5600k and 70 cri 1050 17.2 18.0 2410 2100 134 1400 17.5 24.5 3140 2730 128 1750 17.9 31.3 3840 3340 123 2100 18.3 38.3 4520 3930 118 bxra - 56c5300 - h - xx 5600k and 70 cri 1400 22.7 31.7 4300 3740 136 1750 23.1 40.4 5320 4620 132 2100 23.5 49.4 6300 5480 128 2450 23.8 58.4 7100 6170 122 bxra - 56c9000 - j - xx 5600k and 70 cri 1400 27.8 38.9 5190 4510 133 2100 28.6 60.1 7690 6690 128 2800 29.4 82.3 10060 8750 122 3150 29.7 93.7 11080 9640 118 notes for table 2: 9. values in bold correspond to rated test currents from table 1. alternate values are provide d for reference only and are not guaranteed.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 10 of 28 flux characteristics table 3 : flux characteristics part number [1] cct [2] (kelvin) cri [3] test current [5] (ma) minimum flux [5] (lm) minimum flux [10] (lm) typical flux [6] (lm) typical cbcp [11] (cd) t j = 25oc t case = 85oc t case = 85oc t j = 25oc bxra - 27e3500 - f - 03 2700k 80 1750 2565 2230 2520 920 bxra - 27e4000 - h - 03 2700k 80 2100 4090 3560 4040 1480 bxra - 27e7000 - j - 03 2700k 80 2800 6450 5610 6370 2330 bxra - 27g3500 - f - 03 2700k 90 1750 2270 1970 2190 800 bxra - 27g4000 - h - 03 2700k 90 2100 3490 3030 3440 1260 bxra - 27g7000 - j - 03 2700k 90 2800 5530 4810 5460 2000 bxra - 30e3500 - f - 03 3000k 80 1750 2830 2460 2740 1000 bxra - 30e4000 - h - 03 3000k 80 2100 4440 3860 4380 1600 bxra - 30e7000 - j - 03 3000k 80 2800 7090 6170 7000 2560 bxra - 30g3500 - f - 03 3000k 90 1750 2500 2180 2430 890 bxra - 30g4000 - h - 03 3000k 90 2100 3750 3260 3700 1360 bxra - 30g7000 - j - 03 3000k 90 2800 5990 5210 5910 2160 bxra - 35e3500 - f - 03 3500k 80 1750 2890 2510 2850 1040 bxra - 35e4000 - h - 03 3500k 80 2100 4700 4080 4640 1700 bxra - 35e7000 - j - 03 3500k 80 2800 7510 6530 7420 2720 bxra - 40e4000 - f - 03 4000k 80 1750 3110 2700 3070 1120 bxra - 40e4500 - h - 03 4000k 80 2100 5020 4370 4960 1810 bxra - 40e7500 - j - 03 4000k 80 2800 7930 6900 7840 2870 bxra - 50c4500 - f - xx 5000k 70 1750 3470 3020 3430 1250 bxra - 50c5300 - h - xx 5000k 70 2100 5550 4830 5480 2010 bxra - 50c9000 - j - xx 5000k 70 2800 8860 7710 8750 3200 bxra - 56c4500 - f - xx 5600k 70 1750 3385 2940 3340 1220 bxra - 56c5300 - h - xx 5600k 70 2100 5550 4830 5480 2010 bxra - 56c9000 - j - xx 5600k 70 2800 8860 7710 8750 3200 notes for table 3: 10. minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. based on bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the environment in which the product is operated. 11. center beam candle power is a calculated value based on a lambertian radiation pattern at the rated test current.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 11 of 28 electrical characteristics table 4 : electrical characteristics part number [1] test current [5] (ma) operating voltage t j = 25c [5, 12] (v) typical coefficient of forward voltage [13] (mv/oc) ?vf/?tj typical thermal resistance junction to case (oc/w) rj - c minimum typical maximum bxra - 27e3500 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 27e4000 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 27e7000 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 27g3500 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 27g4000 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 27g7000 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 30e3500 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 30e4000 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 30e7000 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 30g3500 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 30g4000 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 30g7000 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 35e3500 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 35e4000 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 35e7000 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 40e4000 - f - 03 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 40e4500 - h - 03 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 40e7500 - j - 03 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 50c4500 - f - xx 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 50c5300 - h - xx 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 50c9000 - j - xx 2800 26.4 29.4 32.3 - 10 to - 30 0.26 bxra - 56c4500 - f - xx 1750 16.1 17.9 19.7 - 6 to - 18 0.46 bxra - 56c5300 - h - xx 2100 21.1 23.5 25.8 - 8 to - 24 0.31 bxra - 56c9000 - j - xx 2800 26.4 29.4 32.3 - 10 to - 30 0.26 notes for table 4: 12. bridgelux maintains a tester tolerance of 0.10 v on forward voltage measurements. voltage minimum and maximum values at the rated test current are guaranteed by 100% test. 13. typical coefficient of forward voltage maintains a tolerance of 0.1 from nominal current.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 12 of 28 a bsolute maximum ratings table 5 : maximum current and reverse voltage ratings cct [2] (kelvin) part number [1] dc forward current for lm - 80 (ma) [4,5, 6] maximum peak pulsed current (ma) [14, 16] maximum reverse voltage (vr) [15] 2700k bxra - 27e3500 - f - 03 2 100 3000 - 30 bxra - 27g3500 - f - 03 2100 3000 - 30 bxra - 27e4000 - h - 03 2800 4000 - 40 bxra - 27g4000 - h - 03 2800 4000 - 40 bxra - 27e7000 - j - 03 3500 5000 - 50 bxra - 27g7000 - j - 03 3500 5000 - 50 3000k bxra - 30e3500 - f - 03 2100 3000 - 30 bxra - 30g3500 - f - 03 2100 3000 - 30 bxra - 30e4000 - h - 03 2800 4000 - 40 bxra - 30g4000 - h - 03 2800 4000 - 40 bxra - 30e7000 - j - 03 3500 5000 - 50 bxra - 30g7000 - j - 03 3500 5000 - 50 3500k bxra - 35e3500 - f - 03 2 100 3000 - 30 bxra - 35e4000 - h - 03 2800 4000 - 40 bxra - 35e7000 - j - 03 3500 5000 - 50 4000k bxra - 40e4000 - f - 03 2 100 3000 - 30 bxra - 40e4500 - h - 03 2800 4000 - 40 bxra - 40e7500 - j - 03 3500 5000 - 50 5000k bxra - 50c4500 - f - xx 2 100 3000 - 30 bxra - 50c5300 - h - xx 2800 4000 - 40 bxra - 50c90 00 - j - xx 3500 5000 - 50 5600k bxra - 56c4500 - f - xx 2 100 3000 - 30 bxra - 56c5300 - h - xx 2800 4000 - 40 bxra - 56c9000 - j - xx 3 500 5000 - 50 note s for table 5 : 14. bridgelux recommends a maximum duty cycle of 10% when operating led arrays at the maximum peak pulsed current specified. 15. light emitting diodes are not designed to be driven in reverse voltage. 16. m aximum peak pulsed currents are values at which the led array can be driven without catastrophic failures . 17. dc forward current for lm - 80 are the maximum drive currents for which lm - 80 data is currently available 18. lumen maintenance (l70) a nd lifetime predictions are valid for drive current and case temperature cond itions used for lm - 80 testing as included in the applicable lm - 80 test report for these arrays. 19. arrays can be driven at higher cu rrents but l umen maintenance may be reduced
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 13 of 28 absolute maximum ratings (continued) t able 6 : maximum ratings parameter maximum rating led junction temperature 150c storage temperature - 40c to + 1 05 c operating case t emperature 1 05 c soldering temperature [1] 350c or lower for a maximum of 3.5 seconds note for table 6: 20. refer to bridgelux application note an15: reflow soldering of bridgelux led arrays for solder procedure (www,bridgelux.com)
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 14 of 28 forward current versus voltage characteristics figure 2: typical current vs. voltage figure 3: typical current vs. voltage 0.0 0.5 1.0 1.5 2.0 2.5 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 21.0 current (a) forward voltage (v) min max typ min tc=70 bxra - xxx4000 - h - 00, bxra - xxx 4500 - h - 00, bxra - xxx 5300 - h - 00 min vf tc=70c min vf tc=25 c max vf tc=25 c typ vf tc=25 c bxra - xxx3500 - f - 00, bxra - xxx4000 - f - 00, bxra - xxx4500 - f - 00 min vf tc=70c min vf tc=25 c max vf tc=25 c typ vf tc=25 c
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 15 of 28 forward voltage versus current characteristics (continued) figure 4: typical current vs. voltage min vf tc=70c min vf tc=25 c typ vf tc=25 c max vf tc=25 c bxra - xxx7000 - j - 00, bxra - xxx7500 - j - 00, bxra - xxx9000 - j - 00
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 16 of 28 typical relative luminous flux vs. current typical performance at any drive current can be derived from the current versus voltage characteristics shown in figures 2, 3, and 4 and the flux versus current characteristics shown in figures 5 and 6. figure 5 and 6 represent typical performance when pulsed at a junction temperature of 25 degrees celsius. figu re 5: typical flux vs. current bxra - xxx3500 - f - 00 bxra - xxx4000 - f - 00 bxra - xxx 4500 - f - 00
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 17 of 28 typical relative luminous flus vs current (continued) figure 6: typical flux vs. current figure 7: typical flux vs. current bxra - xxx 4000 - h - 00 bxra - xxx 4500 - h - 00 bxra - xxx5300 - h - 00 bxra - xxx 700 0 - j - 00 bxra - xxx7500 - j - 00 bxra - xxx9000 - j - 00
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 18 of 28 typical chromaticity characteristics vs . temperature figure 8: typical flux vs. junction temperature note s for figures 8, 9 and 10 : 1. characteristics shown for warm white 3000k 80cri 2. characteristics shown for neutral white 4000k 80cri 3. character istics shown for neutral white 5000k 7 0cri warm white cool white neutral white 0.0 0.2 0.4 0.6 0.8 1.0 1.2 - 10 0 10 20 30 40 50 60 70 80 90 100 110 normalized luminous flux junction temperature, c figure 9: typical flux vs. junction temperature warm white neutral white cool white
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 19 of 28 typical chromaticity characteristics vs. temperature (continued) figure 9: typical ccy shift vs. junction temperature figure 10: typical ccx shift vs. junction temperature figure 11: typical y shift vs. junction temperature figure 10: typical x shift vs. junction temperature cool white warm white neutral white cool white warm white neutral white - 0.06 - 0.05 - 0.04 - 0.03 - 0.02 - 0.01 0.00 0.01 0.02 - 10 0 10 20 30 40 50 60 70 80 90 100 110 y junction temperature, c warm white cool white neutral white - 0.06 - 0.05 - 0.04 - 0.03 - 0.02 - 0.01 0.00 0.01 0.02 - 10 0 10 20 30 40 50 60 70 80 90 100 110 x junction temperature, c warm white cool white neutral white
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 20 of 28 typical radiation pattern figure 11: typical spatial radiation note s for figure 11 : 1. typical viewing angle is 120 ? 2. viewing angle is defined as the off axis angle from the centerline where vertical intensity is ? of the peak intensity value . figure 12: typical polar radiation pattern 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 relative intensity (%) angular displacement ( )
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 21 of 28 typical spectral characteristics figure 13: typical color spectrum notes for figure 13: 1. color spectra measured at rated current and tj = 25c. 2. color spectrum shown for warm white is 3000k and 80 cri . 3. color spectrum shown for neutral white is 4000k and 80 cri . 4. color spectrum shown for cool white is 5000k and 70 cri . 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110% 400 450 500 550 600 650 700 750 800 relative intensity (%) wavelength (nm) 3000k 4000k 5000k
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 22 of 28 mechanical dimensions figure 14: drawing for rs arrays notes for figure 14 : 1. slots are for m2.5, m3 or #4 screws. 2. sold er pads are labeled + and - to denote positive and negative , respectively. 3. it is not necessary to provide electrical connections to both sets of solder pads. either set of solder pads (6.35 x 2.03 mm rectangula r pads or 3.50 mm tapered square pads) may be used depending on application specific design requirements. 4. drawings are not to scale . 5. d rawing dimensions are in millimeters . 6. unless otherwise specified, tolerances are 0.10 mm. 7. refer to product application notes an10 and an11 for product handling, mounting and heat sink recommendations. 8. the optical center of the led array is nominally defined by the mechanical center of the array. the light emitting surface (les) is centered on the mechanical center of the array to a tolerance of 0.45 mm 9. bridgelux maintains a flatness of 0.25 mm across the mounting surface of the array. refer to application notes an10 and an11 for product handling, mounting and heat sink recommendations. 10. bridgelux recommends four tapped holes for mounting screws C refer to product application note an11 for recommended spacing of holes.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 23 of 28 color binning information figure 15: graph of warm wh ite test bins in xy color space note: 3sdcm bins are shown inside standard ansi bins for comparison purposes. table 7 : warm white xy bin coordinates and associated typical cct bin code x y cct (k) bin code x y cct (k) bin code x y cct (k) x 3 (3sdcm) 0.4148 0.4000 3500 x 3 (3sdcm) 0.4413 0.4107 3000 x 3 (3sdcm) 0.4665 0.4175 2700 0.4047 0.3950 0.4325 0.4075 0.4557 0.4145 0.4012 0.3841 0.4274 0.3958 0.4500 0.4026 0.4098 0.3883 0.4350 0.3984 0.4595 0.4050 0.4148 0.4000 0.4413 0.4107 0.4665 0.4175
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 24 of 28 color binning information (continued) figure 16: graph of neutral wh ite test bins in xy color space note: 3sdcm bins are shown inside standard ansi bins for comparison purposes. table 8 : neutral white xy bin coordinates and associated typical cct bin code x y cct (k) x3 3sdcm 0.3881 0.3879 4000 0.3791 0.3823 0.3769 0.3724 0.3845 0.377 4000k 3sdcm
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 25 of 28 color binning information (continued) figure 17: graph of cool wh ite test bins in xy color space note: 4 sdcm bins are shown inside standard ansi bins for comparison purposes. t able 9 : cool white xy bin c oordinates and associated typical cct bin code x y ansi cct (k) bin code x y ansi cct (k) g3 0.3376 0.3616 5000 e3 0.3215 0.3353 5600 0.3464 0.3688 0.3293 0.3423 0.3452 0.3558 0.3292 0.3539 0.3371 0.3493 0.3207 0.3462 g4 0.3371 0.3493 5000 e4 0.3222 0.3243 5600 0.3452 0.3558 0.3294 0.3306 0.3441 0.3428 0.3293 0.3423 0.3366 0.3369 0.3215 0.3353 h3 0.3464 0.3688 5000 f3 0.3292 0.3539 5600 0.3551 0.376 0.3293 0.3423 0.3533 0.3624 0.3371 0.3493 0.3452 0.3558 0.3376 0.3616 h4 0.3452 0.3558 5000 f4 0.3294 0.3306 5600 0.3533 0.3624 0.3366 0.3369 0.3515 0.3487 0.3371 0.3493 0.3441 0.3428 0.3293 0.3423 x4 (4sdcm) 0.3499 0.3657 5000 x4 (4sdcm) 0.3332 0.3517 5600 0.3412 0.3585 0.3247 0.3440 0.3407 0.3461 0.3255 0.3330 0.3481 0.3520 0.3327 0.3393
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 26 of 28 color control options r s led series arrays are available in the following color control opt ions. table 10 : color control options product cct cri 3 sdcm part number 4 sdcm part number 7sdcm part number rs led array 2700k 80 bxra - 27e3500 - f - 03 not available not available rs led array 2700k 90 bxra - 27g3500 - f - 03 not available not available rs led array 2700k 80 bxra - 27e4000 - h - 03 not available not available rs led array 2700k 90 bxra - 27g4000 - h - 03 not available not available rs led array 2700k 80 bxra - 27e7000 - j - 03 not available not available rs led array 2700k 90 bxra - 27g7000 - j - 03 not available not available rs led array 3000k 80 bxra - 30e3500 - f - 03 not available not available rs led array 3000k 90 bxra - 30g3500 - f - 03 not available not available rs led array 3000k 80 bxra - 30e4000 - h - 03 not available not available rs led array 3000k 90 bxra - 30g4000 - h - 03 not available not available rs led array 3000k 80 bxra - 30e7000 - j - 03 not available not available rs led array 3000k 90 bxra - 30g7000 - j - 03 not available not available rs led array 3500k 80 bxra - 35e3500 - f - 03 not available not available rs led array 3500k 80 bxra - 35e4000 - h - 03 not available not available rs led array 3500k 80 bxra - 35e7000 - j - 03 not available not available rs led array 4000k 80 bxra - 40e4000 - f - 03 not available not available rs led array 4000k 80 bxra - 40e4500 - h - 03 not available not available rs led array 4000k 80 bxra - 40e7500 - j - 03 not available not available rs led array 5000k 70 not available bxra - 50c4500 - f - 04 bxra - 50c4500 - f - 00 rs led array 5000k 70 not available bxra - 50c5300 - h - 04 bxra - 50c5300 - h - 00 rs led array 5000k 70 not available bxra - 50c9000 - j - 04 bxra - 50c9000 - j - 00 rs led array 5600k 70 not available bxra - 56c4500 - f - 04 bxra - 56c4500 - f - 00 rs led array 5600k 70 not available bxra - 56c5300 - h - 04 bxra - 56c5300 - h - 00 rs led array 5600k 70 not available bxra - 56c9000 - j - 04 bxra - 56c9000 - j - 00 note: color control marking array part numbers are shown in the tables above. arrays are tested, binned and marked with the appropriate sub - bin. warm and neutral white arrays are tested to 3sdcm (marked as x3). cool white arrays are tested to 4sdcm (marked as x4). cool white arrays are tested to 7sdcm (marked with sub - bin).
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 27 of 28 design resources bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with bridgelux led array products. included below is a list of available resources which can be downloaded from the bridgelux web site under the design resources section. these documents are updated regularly as new information becomes available, including complimentary infrastructure products such as commer cially available secondary optics and electronic driver solutions. application notes ? an10: effective thermal management of bridgelux led arrays ? an11: assembly considerations for bridgelux led arrays ? an12: electrical drive considerations for bridgelux led arrays ? an14: reliability data sheet for bridgelux led arrays ? an15: reflow soldering of bridgelux led arrays ? an16: optical considerations for bridgelux led arrays optical source models optical source models and ray set files are available for all bridgelux led array products, and can be downloaded directly from the bridgelux web site. the list below contains the formats currently available. if you require a specific format not included i n this list , please contact your bridgelux sales representative for assistance . ? zemax ? asap ? iesna ? lighttools ? lucidshape ? optis speos ? photopia ? tracepro ? radiant imaging source model 3d cad models three dimensional cad models depicting the product outline of all bridgelux led arrays are ava ilable in both sat and step formats. these cad files can be downloaded directly from the bridgelux web site.
bridgelux rs array series product data sheet ds 25 (8/30/2013 rev 3 ) page 28 of 28 about bridgelux bridgelux is a leading developer and manufacturer of technologies and solutions transforming the $40 billion global lighting industry into a $100 billion market opportunity. based in livermore, california, bridgelux is a pioneer in solid - state lighting (s sl), expanding the market for light - emitting diode (led) technologies by driving down the cost of led lighting systems. bridgeluxs patented light source technology replaces traditional technologies (such as incandescent, halogen, fluorescent and high int ensity discharge lighting) with integrated, solid - state lighting solutions that enable lamp and luminaire manufacturers to provide high performance and energy - efficient white light for the rapidly growing interior and exterior lighting markets, including s treet lights, commercial lighting and consumer applications. bridgelux is the only vertically integrated led manufacturer and developer of solid - state light sources that designs its solutions specific ally for the lighting industry. for more information ab out the company, please visit www.bridgelux.com ? 2013 bridgelux, inc. all rights reserved. product specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of BXRA-27E4000-H-03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X